Jump to main content

Range & stove repair in San Antonio, fixed at your place.

Under one cabinet, a range is really two appliances. Here is how we separate a cooktop fault from an oven fault, and what San Antonio homes need to know about gas and propane.

Phones staffed 24/7Three-hour arrival window90-day parts warranty

Diagnosis
The failed part is found before any price
Approval
No work begins without your okay
Hours
Calls answered day and night
Warranty
Parts 90 days · labor 30 days

Book online

Send the basics. A dispatcher calls you back.

  1. 1Describe the problemYour ZIP code, the appliance, and the trouble it is giving you.
  2. 2Pick up when we callWe confirm the address and set a three-hour arrival window.
  3. 3Get one priceThe technician diagnoses it, then quotes parts and labor together. The diagnostic fee is credited if you go ahead.

Would rather explain it out loud? Call us any hour, any day.

Schedule a repair

Step 1 of 2 · Appliance and area

Step 1 of 2

Appliance and area

Which appliance?

Appliance

Where in the San Antonio area?

Booking costs nothing, and we never ask for a card.

Prefer to call? (210) 939-3313

1–2.5 hours
Typical time on site
45
Range & Stove faults we fix
31
Brands we service
24/7
Phones answered

Range & Stove problems

What is wrong with your range & stove?

Pick a symptom for the usual causes and the fix a technician makes.

  • Stove oven won't heat but burners workThe cooktop works and the oven stays cold, which tells you the problem sits in the oven circuit. On a gas range it's often a weak igniter. On an electric range it's often the bake element, or one half of the 240-volt supply.

    Typical culprits

    • Electric range bake element burnt through
    • Gas oven igniter glowing but too feeble for the safety valve
    • Oven safety valve failed
    • Temperature sensor open
    • Control board bake relay not closing
    • One leg of the 240-volt circuit tripped

    How the technician handles it

    We check the supply, then test the element or igniter current, the valve, the sensor and the control output in that order. We put in a new part, then run the oven through a full preheat to confirm the fix.

  • One stove burner not workingA single burner or element stays cold while the rest of the stove works. Each position has its own switch, valve or igniter, so the fault is usually limited to that one spot.

    Typical culprits

    • Radiant or coil element burnt out
    • Infinite switch for that position failed
    • Gas burner ports clogged
    • Igniter cracked
    • Element socket burnt

    How the technician handles it

    On coil tops we swap in a known-good element to test the socket; on glass tops we test the switch and radiant element; on gas we check ports, caps and spark. Only the bad part is replaced.

  • Range control board faultThe control runs the oven and sometimes the cooktop. A bad control board can leave the display dead, throw strange error codes, or keep the oven from heating or from shutting off.

    Typical culprits

    • Relay welded or burnt
    • Heat damage from self-clean
    • Power surge from a storm
    • Moisture from a boil-over

    How the technician handles it

    We test sensors, elements and wiring first, then confirm the board fault. A new board is installed and every function tested.

  • Gas stove burner won't lightThe igniter clicks but the burner won't catch, or there's no click at all. Most often the burner cap is sitting crooked or the igniter got wet.

    Typical culprits

    • Burner cap out of position
    • Igniter wet or dirty
    • Spark module failed
    • Burner ports blocked

    How the technician handles it

    We seat the cap, clean the ports and igniter and check spark strength. If all burners are weak, we test the module and replace it if needed.

  • Gas smell from the stoveA strong or lingering gas smell is an emergency. Don't light anything or touch switches.

    Typical culprits

    • Loose fitting at the regulator or manifold
    • Burner valve leaking
    • Old flex connector
    • Oven safety valve not closing
    • Knob left partly on

    How the technician handles it

    Get everyone outside, and once you're well away from the house, call CPS Energy, your gas supplier or 911. After the utility makes it safe, we repair the source and leak-test every connection.

  • Range self-clean problemSelf-clean refuses to start, quits partway, or leaves the door locked. The extreme heat of the cycle exposes weak parts.

    Typical culprits

    • Door lock motor failed
    • Thermal fuse blown
    • Sensor out of range at high heat
    • Control relay failing under load

    How the technician handles it

    We test the lock, fuse, sensor and relays and replace the failed part. We'll also advise on when it's best to run self-clean.

  • Range oven temperature offBakes run longer or shorter than the recipe says. Check with an oven thermometer over several readings before deciding.

    Typical culprits

    • Sensor drifting
    • Sensor touching the oven wall
    • Control offset changed
    • Door gasket leaking

    How the technician handles it

    We measure the average temperature, test the sensor and set the calibration offset if the parts are fine.

  • Range oven door hinge brokenThe door hangs crooked, drops open or won't close. Heavy doors and pots rested on the open door strain hinges.

    Typical culprits

    • Hinge spring broken
    • Hinge arm bent
    • Hinge receiver in the frame worn
    • Heavy pots rested on the open door

    How the technician handles it

    We replace both hinges, check the receivers and confirm the door seals evenly.

  • Stove not levelOil pools on one side of the skillet, or cakes come out lopsided. Slab movement on clay soils and new flooring can throw a stove out of level.

    Typical culprits

    • Legs not adjusted
    • Floor uneven or slab shifted
    • Leg broken or missing
    • Range not seated against the anti-tip bracket

    How the technician handles it

    With a bubble level on the rack we level the range, swap out broken legs and check that the anti-tip bracket has caught the rear leg.

  • Range convection fan not runningConvection settings cook slowly and unevenly because the rear fan isn't moving air.

    Typical culprits

    • Fan motor failed
    • Fan blade loose on the shaft
    • Relay on the control failed
    • Fan wiring or connector burnt or loose

    How the technician handles it

    The fan motor, element and relay get tested, and the part that failed gets replaced.

  • Range broiler not workingThe broil element doesn't glow. Preheat may also be slower, since many ovens use the broil element to preheat.

    Typical culprits

    • Broil element burnt out
    • Broil relay failed
    • Loose terminal
    • Grease splatter damaging the element

    How the technician handles it

    We test the element and relay, replace the failed part and test broil and bake.

  • Range oven running way too hotFood burns fast or the oven keeps heating after it's off. Turn off the breaker or gas until it's checked.

    Typical culprits

    • Control relay stuck closed
    • Sensor reading low
    • Sensor disconnected
    • Sensor wiring damaged behind the range

    How the technician handles it

    We test the sensor and the relay, replace the failed part and check the oven shuts off properly.

  • Electric range trips the breakerThe breaker trips when you use the range or a certain element. There's a short somewhere. Keep that breaker off; flipping it back on before the short is found just trips it again, or worse.

    Typical culprits

    • Element shorted
    • Terminal block burnt
    • Cord damaged
    • Moisture in a surface element

    How the technician handles it

    We test each element, the terminal block and the cord for shorts and replace what's damaged. If the house wiring is at fault, we'll recommend an electrician.

  • Range oven door locked shutThe door stays locked after self-clean or locks on its own. Wait until the oven is fully cool first.

    Typical culprits

    • Lock motor failed
    • Lock switch fault
    • Control fault
    • Oven still above the unlock temperature

    How the technician handles it

    We test the lock motor, switches and control, release the door and replace the failed part.

  • Range oven door glass brokenDon't use the oven again until cracked or shattered door glass has been replaced.

    Typical culprits

    • Cold water on hot glass
    • Impact from a pan or rack
    • Self-clean heat stress
    • Glass chipped at the edge

    How the technician handles it

    We take the door apart, replace the glass panel and reassemble it correctly.

  • Range oven door gasket wornHeat leaks around the door, the knobs get hot and baking slows. The gasket has likely flattened or torn.

    Typical culprits

    • Gasket hardened
    • Gasket torn
    • Clips broken
    • Gasket burnt by self-clean

    How the technician handles it

    We install a new gasket with its clips and confirm a good seal all around.

Show 29 more range & stove problems
  • Range oven preheats slowlyPreheating drags on far longer than it used to, which you really notice when cooking for a big group.

    Typical culprits

    • Weak igniter on a gas range
    • Broil element out on an electric range
    • Gasket leaking
    • Temperature sensor drifting

    How the technician handles it

    We time a preheat, then check the igniter or the broil and bake elements, the door gasket and the temperature sensor until the weak link shows itself.

  • Range oven smoking a lotSmoke from a spill is common. Smoke from an empty oven, or with an electrical smell, is not.

    Typical culprits

    • Spills on the oven floor
    • Grease on the broil element
    • Wiring overheating
    • Element shorting

    How the technician handles it

    We trace where it is coming from, clean off what is burning, and check the elements and their wiring. Damaged wiring is replaced.

  • Gas range oven igniter weakThe igniter lights up orange, yet the oven takes ages to light or doesn't light. Of all gas oven faults, a worn-out igniter tops the list.

    Typical culprits

    • Igniter worn with age
    • Igniter cracked
    • Loose connector
    • Low supply voltage at the igniter

    How the technician handles it

    We measure the igniter current, replace it with the correct part and leak-check the area.

  • Gas range oven safety valve failedYou see the igniter glowing, yet no gas reaches the burner. Either the safety valve itself is dead, or the igniter pulls too little current to trip it open.

    Typical culprits

    • Valve coil failed
    • Valve stuck closed
    • Igniter too weak to open the valve
    • Wiring fault between igniter and valve

    How the technician handles it

    We test the igniter first, since a weak one mimics a failed valve. If the valve is bad, we replace it and leak-test.

  • Upper or lower cavity dead on a double-oven rangeOne cavity heats and the other doesn't. Each has its own heat source, sensor and relay.

    Typical culprits

    • Element or igniter failed in one cavity
    • Sensor failed for that oven
    • Board relay failed for that oven
    • Door switch for that oven faulty

    How the technician handles it

    We test the parts for the cold oven and replace the failed one, then test both ovens.

  • Range display missing segmentsNumbers are partly missing or hard to read, making it hard to set the oven.

    Typical culprits

    • Display board failed
    • Heat damage from self-clean
    • Ribbon cable loose
    • Moisture behind the panel

    How the technician handles it

    We check the cable and connections and replace the display or control board if needed.

  • Stove dead after a power outageAfter a storm or outage, the range won't turn on. Sometimes it just needs a reset. Sometimes the surge did damage.

    Typical culprits

    • Breaker tripped
    • Control fuse blown
    • Board damaged by a surge
    • Terminal block connection loose

    How the technician handles it

    Shut the breaker off for roughly a minute, then turn it on again. If it's still dead, we test the supply, fuses and board and replace what failed.

  • Stove burner switch faultyAn element stays cold, only works on high or cuts in and out. Most of the time it's the switch mounted behind that knob.

    Typical culprits

    • Switch contacts burnt
    • Switch stuck
    • Loose terminal at the switch
    • Wiring burnt from a loose connection

    How the technician handles it

    We test the switch and wiring, then replace the switch and any burnt terminals.

  • Range cord or outlet burntA burnt smell at the back of the range, scorch marks on the cord or a range that cuts out can mean a burnt connection. This is a fire risk. Turn off the breaker.

    Typical culprits

    • Loose connection at the terminal block
    • Corroded terminals
    • Old cord
    • Worn outlet

    How the technician handles it

    We replace the cord and terminal block and tighten connections properly. If the wall outlet is damaged, we'll recommend an electrician.

  • Induction range won't detect the panThe zone flashes and won't heat. Most of the time the pan isn't suited to induction.

    Typical culprits

    • Pan not magnetic
    • Pan too small
    • Sensor fault
    • Power board fault

    How the technician handles it

    Test the pan with a magnet. If good pans aren't detected, we test the sensor and board.

  • Dual-fuel range oven not heatingGas burners work but the electric oven doesn't. A dual-fuel range needs a 240-volt circuit for the oven as well as gas for the top.

    Typical culprits

    • Bake element failed
    • Sensor fault
    • Control fault
    • 240-volt supply with one leg dead

    How the technician handles it

    We check both legs of the supply, test the element and sensor and replace the failed part.

  • Gas stove not converted to propaneYellow flames, soot, smell or burners that are too big are common when a natural gas range is hooked up to propane. This is a safety issue.

    Typical culprits

    • Wrong orifices
    • Regulator not converted
    • Oven orifice not changed
    • Simmer settings not adjusted

    How the technician handles it

    Turn the range off. We convert all burners and the oven, set the regulator and simmer screws and leak-test everything.

  • Range cooling fan won't stop after the oven is turned offIt's normal for the cooling fan to run a while after cooking. One that never stops isn't.

    Typical culprits

    • Long cooldown that is normal for the model and mistaken for a fault
    • Thermostat stuck closed
    • Relay stuck
    • Fan wiring fault

    How the technician handles it

    We check whether it's normal cooldown for your model, then test the thermostat and relay if it runs too long.

  • Range oven shuts off during cookingThe oven turns itself off partway through a bake, which can ruin a holiday roast.

    Typical culprits

    • Auto shut-off setting
    • Overheating cutout tripping
    • Control fault
    • Loose connection

    How the technician handles it

    We check the settings, test the cutout and look for loose connections. If the 12-hour automatic shut-off is ending the bake, switching that feature off or using Sabbath mode solves it.

  • Stove tips forwardWeight on the open door can tip a freestanding range, and that is a serious danger to children. The anti-tip bracket prevents that.

    Typical culprits

    • No anti-tip bracket after a move or a flooring job
    • Bracket not engaged with the rear leg
    • Floor uneven
    • Leveling leg set too high to catch the bracket

    How the technician handles it

    We install or reposition the bracket, level the range and confirm the rear leg locks under it.

  • One gas stove burner has a yellow flameOne burner burns yellow while the others are blue. That points to that burner's ports, cap or orifice.

    Typical culprits

    • Burner ports dirty
    • Cap misaligned
    • Air shutter out of adjustment
    • Orifice partly blocked

    How the technician handles it

    We clean the burner and orifice, reseat the cap and adjust the air where possible.

  • Gas stove pilot won't stay litOn older stoves with standing pilots, the thermocouple tells the valve the pilot is lit. If that part goes bad, the pilot dies as soon as you release the knob.

    Typical culprits

    • Thermocouple worn
    • Pilot too small to keep the thermocouple hot
    • Pilot orifice dirty
    • Loose connection at the safety valve

    How the technician handles it

    We clean the pilot, adjust the flame and replace the thermocouple if needed, then leak-test.

  • Gas stove pilot light keeps going outOlder stoves with standing pilots can lose them to drafts, grease or a dirty orifice.

    Typical culprits

    • Pilot orifice clogged
    • Draft from a window, door or fan
    • Pilot adjustment too low
    • Grease around the pilot

    How the technician handles it

    We clean the pilot, set its flame and check for drafts. If the pilot hardware is worn, we replace it.

  • Lighting a gas stove when the power is outMost gas stoves need electricity for the spark. In an outage, they won't light by themselves.

    Typical culprits

    • Power outage
    • Cord unplugged
    • Outlet or GFCI tripped
    • Spark module fuse blown

    How the technician handles it

    When the power is out, gas burners can usually be lit with a long match, carefully. Gas ovens with glow-bar igniters won't work without power. If power is on and there's no spark, we check the outlet, cord and module.

  • Stove burner won't hold a low simmerThe flame goes out on low or stays too high.

    Typical culprits

    • Simmer screw out of adjustment
    • Burner ports dirty
    • Wrong gas setup after conversion
    • Burner cap misplaced

    How the technician handles it

    The burner gets cleaned, the cap gets checked, and the simmer setting is adjusted to match your gas type.

  • Electric stove burner stuck on highA burner element that won't shut off or stays stuck on high is a fire hazard. Turn off the breaker.

    Typical culprits

    • Infinite switch contacts welded
    • Wiring short
    • Switch melted from a loose terminal
    • Control relay stuck on electronic models

    How the technician handles it

    With power off, we replace the switch and any damaged wiring, then test every element.

  • Stove keeps clicking after the burner lightsThe igniter keeps sparking with the flame on. Reignition stoves do this if they can't sense the flame.

    Typical culprits

    • Igniter dirty
    • Cap not seated
    • Spark module fault
    • Poor ground at the burner

    How the technician handles it

    We clean the igniter, seat the cap and check the ground and module.

  • Coil stove element sparks or flickersA burnt socket shows up as sparking, flickering, or an element that only works when you wiggle it.

    Typical culprits

    • Socket burnt
    • Element loose in the socket
    • Terminals corroded
    • Spills reaching the socket

    How the technician handles it

    We replace the socket, usually the element too, and check the wiring.

  • Stove burner lights then goes outThe flame catches and then dies. On stoves with flame safety, the sensor isn't confirming the flame.

    Typical culprits

    • Flame sensor or thermocouple fault
    • Burner cap misplaced
    • Low gas pressure
    • Drafts blowing out the flame

    How the technician handles it

    The cap gets checked, the flame sensor or thermocouple is tested, and we measure gas pressure.

  • Stove knob spins without controlThe knob turns freely but doesn't change the flame or heat.

    Typical culprits

    • Knob insert worn
    • Valve shaft stripped
    • Switch shaft broken
    • Knob cracked

    How the technician handles it

    We replace the knob, or the valve or switch if the shaft is damaged.

  • Stove controls lockedThe panel shows a lock and won't respond.

    Typical culprits

    • Lock turned on
    • Keypad fault
    • Control board fault
    • Lock left on after self-clean

    How the technician handles it

    We show you how to release it, then test the keypad and board if it won't.

  • Stove takes too long to boil waterA pot that used to boil quickly now takes much longer.

    Typical culprits

    • Burner ports clogged
    • Gas pressure low
    • Element weak
    • Pan too small or warped

    How the technician handles it

    We clean the burner, check gas pressure or element output and recommend cookware changes if needed.

  • Burning smell from a new stoveFor the first few uses a new stove may give off a smell while the factory coatings burn away. A smell that lingers, or smells electrical, needs a check.

    Typical culprits

    • Factory coatings burning off
    • Packing material left inside
    • Wiring fault
    • Shipping tape on an element

    How the technician handles it

    Run the oven empty with ventilation. If the smell continues, we check for packing material and wiring faults.

  • Spill got into the stove controlsA boil-over can soak spark switches and controls, causing clicking or dead burners.

    Typical culprits

    • Water on spark switches
    • Sugar residue on switches
    • Corroded wires
    • Liquid in the burner box

    How the technician handles it

    We let it dry, clean residue and replace damaged switches or wires.

Brands

Range & Stove brands we repair

All brands →
  • Samsung logo
  • LG logo
  • Whirlpool logo
  • GE Appliances logo
  • Maytag logo
  • Bosch logo
  • KitchenAid logo
  • Frigidaire logo
  • Viking logo
  • Kenmore logo
  • Amana logo
  • Electrolux logo
  • Miele logo
  • Thermador logo
  • Wolf logo
  • Admiral logo
  • AGA logo
  • Avanti logo
  • Bertazzoni logo
  • Blomberg logo
  • Dacor logo
  • DCS logo
  • Fisher & Paykel logo
  • Gaggenau logo
  • Hotpoint logo
  • JennAir logo
  • La Cornue logo
  • Roper logo
  • Smeg logo
  • Thor Kitchen logo
  • Vulcan logo

From our technicians

Range & Stove repair notes for San Antonio homes

When a range acts up, the first question is which half is affected. Burners dead but oven fine, or oven cold but burners lighting, tells us a lot. Faults confined to one side point to a part on that side. Both sides failing together points to the shared parts: the power supply, the gas supply or the control.

Ranges come in many types: gas, electric coil, smooth glass, dual-fuel with a gas top and electric oven, and induction. Freestanding stoves, slide-ins and pro-style ranges all appear in San Antonio kitchens. Older homes in neighborhoods like Monte Vista and King William sometimes still have vintage stoves with standing pilots, while new subdivisions often have all-electric or induction ranges.

Fuel matters too. CPS Energy supplies natural gas in much of the city, many newer neighborhoods are all-electric, and Hill Country homes often cook on propane. A gas range must match its fuel, and moving one between natural gas and propane without converting it is unsafe.

Sorting a range fault in five minutes

Our technicians start by asking what works. If every burner and the oven are dead, we check the breaker, the cord or terminal block and the control. On an electric range, if the cooktop works but the oven doesn't, one leg of the 240-volt circuit may be off. If the oven is cold on a gas range, we look at the igniter, which is the most common gas oven failure.

For burner problems we go position by position: element, switch and socket on coil tops, element and switch on glass, and cap, ports, igniter and valve on gas. Only then do we look at the board.

Propane, natural gas and conversions

Gas ranges ship set up for natural gas. Homes on propane, common around Boerne, Bulverde, Helotes and other Hill Country areas, need the range converted. Conversion means changing the burner and oven orifices, setting the regulator for propane and adjusting the simmer settings. A partial conversion, like changing the top burners but not the oven, is a common source of soot, yellow flames and odors.

If you've just moved a range, or bought a new one for a propane home, ask whether it was converted. Signs it wasn't include tall yellow flames, soot on pans, a strong smell and burners that won't simmer. Turn the range off and call us or the propane supplier.

Anti-tip brackets, leveling and moving day

Every freestanding range needs an anti-tip bracket that anchors its rear leg to the wall or floor. They often get left off after a floor replacement or a move, and military families who move often on PCS orders may find the bracket missing in a rental. A range missing one can pitch forward when somebody leans on the open door. We check it on every range call.

Leveling matters too. On the east and south sides, expansive clay can move slabs over the years, and an unlevel range bakes unevenly and sends oil to one side of the pan.

Safety and what you can do yourself

A gas smell means no switches, no lighters and no flames, not even to check a burner. Get everyone outside, and once you're well away from the house, call CPS Energy, your gas supplier or 911. Before moving a range or touching anything behind it, shut off the gas and turn off the breaker or unplug it. A burnt smell at the back of an electric range can be a burnt cord or terminal block, which is a fire risk.

Safe owner care includes cleaning burner caps and heads, drying wet igniters, cleaning spills before they bake on, replacing a burnt-out coil element of the right type, and keeping foil off the oven floor. Leave valves, igniters, switches and boards to a technician. On repair versus replace, most range repairs are worth doing. The case for replacing grows with rust, an obsolete board or repeated failures.

Questions

Range & Stove repair questions

Why do my stove burners work but the oven won't heat?

On a gas range it's usually a weak oven igniter. On an electric range it may be the bake element, or one half of the 240-volt circuit is off. We check the supply, element or igniter, sensor and control.

Does my gas range need to be converted for propane?

Yes. Ranges ship set up for natural gas. On propane, the burner and oven orifices, regulator and simmer settings must all be converted. A partial conversion causes soot and yellow flames and is unsafe.

Can I use my gas stove during a power outage?

You can usually light the burners carefully with a long match, but glow-bar igniters in gas ovens need electricity to work. Be careful and keep the kitchen ventilated.

My range smells like gas. What do I do?

Walk out without flipping anything on or off, and make the call to your gas supplier or 911 from the yard or the street. We repair the range after the utility makes the home safe.

What is an anti-tip bracket for on my range?

A freestanding range missing one can tip forward when a person leans on the open door. Brackets often go missing after moves or new floors. We check it on every range visit.

What happens during a range repair visit?

You get a three-hour arrival window. Our technician works out which half has the problem, tests those parts, and quotes a single parts-and-labor price before starting. Gas repairs end with a leak test.

Need your range & stove looked at?

Phone us at any hour, or send the online form and we ring back to set your three-hour window.

Call now, 24/7(210) 939-3313Book online